Victron BPR000100400 BatteryProtect 12/24V 100A Battery Protection Unit

$52.98 USD

The Victron BPR000100400 BatteryProtect guards 12V and 24V batteries by disconnecting non-essential loads as they near full discharge. It detects the system voltage automatically and has a 7-segment LED display for setting its voltage levels.

Ships from manufacturer within 2 weeks

SKU: BPR000100400 Category: Tags: , , , Brand:

Description

The Victron BPR000100400 is a BatteryProtect unit for 12V and 24V battery systems. It disconnects non-essential loads when the battery risks full discharge. It uses a 7-segment LED display for programming and draws very little current, whether it is on or off.

Features

  • 7-segment LED display for viewing and adjusting settings during setup.
  • Detects automatically whether it is connected to a 12V or 24V system, so voltage does not need to be set by hand.
  • Programmable engage and disengage voltage levels to suit the battery type.
  • Over voltage protection disconnects loads if DC voltage exceeds 16V or 32V.
  • Keeps loads connected for 90 seconds after an alarm triggers, then reconnects them automatically once normal voltage returns.
  • Current draw of less than 1.5 mA when active and 0.6 mA in shutdown mode.
  • IP67 (potted) rating.

Specifications

Part number (MPN) BPR000100400
UPC 8719076021438
Battery system voltage 12V and 24V (detected automatically)
Max Continuous Load Current 100A
Peak Current (30 seconds) 600A
Operating Voltage Range 6 – 35V
Over voltage disconnect 16V or 32V
Current Consumption (On) 1.5 mA
Current Consumption (Off) 0.6 mA
Load Disconnect Delay 90 seconds
Load Reconnect Delay 30 seconds
Alarm Output Delay 12 seconds
Maximum Load on Alarm Output 50 mA
Operating Temperature Range -40°C to 40°C (up to 60% of nominal load at 50°C)
IP Rating IP67 (potted)
Weight 0.5 kg (1.1 lbs)
Dimensions (hxwxd) 59 x 42 x 115 mm

Compatibility

Victron states that the BatteryProtect can be integrated with VE.Bus Battery Management Systems for Li-ion batteries.