Description
The Victron PIN243020000 Phoenix Inverter converts power from a 24V battery bank into 230 VAC for equipment that needs AC power. It is a true sine wave inverter with 3000 VA continuous output at 25°C, a VE.Bus port for parallel and three-phase operation, and a 19-33 V DC input range.
Features
- True sine wave output built on hybrid HF technology, with maximum efficiency listed at 94%.
- Extra start-up power for difficult loads, such as computers and low power electric tools.
- Up to 6 units can run in parallel for higher output, and 3-phase operation is also possible.
- RS-485 port for computer connection; the MK3-USB VE.Bus to USB interface is listed as an accessory.
- VEConfigure software, downloadable from the Victron website, can set output voltage and frequency, over and under voltage limits, and the relay.
- Programmable relay that Victron says can signal alarm conditions or start a generator.
- Filax automatic transfer switch is listed for this inverter, with a switchover time of less than 20 milliseconds.
Specifications
| Part number | PIN243020000 |
| Brand | Victron Energy |
| Continuous power at 25°C | 3000 VA / 2400 W (Inverter) |
| Continuous power at 40°C | 2200 W (Inverter) |
| Peak power | 6000 W (Inverter) |
| DC input voltage | 19-33 V (Inverter) |
| Output AC voltage | 230 VAC ±3% (Inverter) |
| Output AC frequency | 50/60 Hz ±0.1% (Inverter) |
| Maximum efficiency | 94% (Inverter) |
| Zero-load power | 20 W (Inverter) |
| Protection category | IP21 |
| Protection | A-G |
| Battery connection | 2+2 M8 Bolts |
| Operating temperature | -40 to 65°C |
| Remote on/off | Yes |
| Automatic transfer switch | Filax |
| Parallel, 3-phase and split-phase operation | Yes |
| Programmable relay | Yes |
| 120 VAC/230 VAC connection | Screw terminals |
| Cooling | Fan assisted |
| Material | Aluminum |
| Colour | Blue (RAL 5012) |
| Dimensions | 362 mm (H) x 258 mm (W) x 218 mm (D) |
| Weight | 18 lb |
Compatibility
Victron lists these products alongside the Victron PIN243020000 inverter: the Color Control GX, the MK3-USB VE.Bus to USB interface, the VE.Bus to NMEA 2000 interface and the BMV-700 Battery Monitor. The page also says the inverter can be connected to VENet and to other computerized monitoring and control systems.