Description
The Victron MultiPlus-II 24/3000/70-50 2x120V is an inverter charger for standard North American 120/240 VAC split-phase setups, with a 50 A transfer switch and 3,000 VA continuous output at 25 C. It can take in shore power or generator power on both lines and pass it through to loads.
Features
- Passes through both lines of a 120/240 VAC split-phase supply and can use the full 50 A for charging and AC loads.
- In inverter mode, L1 and L2 are connected together to supply 120 VAC to loads on either output.
- 240 VAC is only available from a split-phase 120/240 VAC supply, which keeps heavy loads such as water heaters from discharging the battery.
- Two AC outputs, a 70 A maximum battery charge current and 3,000 VA continuous output at 25 C.
- Two RJ45 VE.Bus communication ports, and M8 bolts for the battery connection (two positive, two negative).
- Victron says it is suitable for LiFePO4 batteries and a variety of other battery technologies.
- Victron says the range supports parallel and 3ph configuration for larger capacity VE.Bus systems.
Specifications
Specifications for the Victron MultiPlus-II 24/3000/70-50 2x120V, part PMP242305132.
| Part number | PMP242305132 |
| Model | MultiPlus-II 24/3000/70-50 2x120V 50/60Hz (UL 458) |
| Cont. output power at 25 C | 3,000 VA |
| Cont. output power at 25 C | 2,400 W |
| Peak power | 5,500 W |
| Max. battery charge current | 70 A |
| Transfer switch | 50 A |
| VE.Bus communication port | Two RJ45 terminals |
| Battery connection | M8 bolts (two for positive and two for negative connection) |
| 230-VAC connection | Screw terminals 21 mm² (4 AWG) |
| Dimensions (HxWxD) | 578 x 275 x 148 mm |
| Weight | 22 kg |
Certificates and warranty
Victron’s certificate list includes a UL 458 safety certificate for the MultiPlus-II 2x 120V. Victron offers a 5-year standard warranty with global repair service.