Victron CSE000100000 AC Current Sensor for PV Inverters

$48.71 USD

Victron CSE000100000 AC Current sensor is an external unit that measures AC current on a PV inverter, feeding solar production readings to a GX device. Dipswitches choose a 1.5 kW, 3 kW, 5 kW or 7 kW range, and it has protection category IP54.

Ships from manufacturer within 2 weeks

SKU: CSE000100000 Category: Tags: , Brand:

Description

The Victron CSE000100000 AC Current sensor measures the AC current of a PV inverter, so solar production can be shown on a GX device and the VRM Portal. Combined with voltage measurements, it is used to calculate apparent power (VA) and energy (kWh). It is a simple external sensor that wires to a Multi or Quattro inverter/charger.

Features

  • Installs by passing one of the PV inverter’s AC wires through the sensor.
  • Dipswitches set the power range to 1.5 kW, 3 kW, 5 kW or 7 kW. Choose the range equal to or higher than the highest expected power.
  • Connects to the TEMP-sense input of Multi and Quattro models. The AUX input is suitable only on some hardware.
  • Up to 9 sensors in one system. A multi-phase PV inverter needs one sensor per phase, wired to the Multi in the same phase.
  • Protection category IP54.
  • Readings appear on the GX device and the VRM Portal.
  • Needs a Multi or Quattro with the newer microprocessor, identified by a 7-digit firmware version starting with 26 or 27.

Specifications

Part number CSE000100000
Current type AC
Power range 1.5 kW, 3 kW, 5 kW, 7 kW (set with dipswitches)
Dipswitch setting for 1.5 kW all off
Dipswitch setting for 3 kW 1
Dipswitch setting for 5 kW 1,2
Dipswitch setting for 7 kW 1,2,3
Max measured current 8 A (1.5 kW), 16 A (3 kW), 25 A (5 kW), 30.5 A (7 kW)
Max input current 9 A (1.5 kW), 18 A (3 kW), 30 A (5 kW), 40 A (7 kW)
Power step size, 230V AC (approx., depends on input voltage) 9 W (1.5 kW), 17 W (3 kW), 30 W (5 kW), 35 W (7 kW)
Power step size, 120V AC (approx., depends on input voltage) 4.5 W (1.5 kW), 8.5 W (3 kW), 15 W (5 kW), 17.5 W (7 kW)
Max number of sensors in one system 9
Protection category IP54

Compatibility

Victron’s compatibility list names the supported MultiPlus, Quattro and Multi-G models and the input each one uses. The AUX input depends on hardware, so check the serial number list before using it.

  • The Multi or Quattro needs the newer microprocessor: a 7-digit firmware version starting with 26 or 27. Older control boards start with 19 or 20 and are incompatible.
  • Connect the Multi or Quattro to the VE.Bus port of the Color Control GX. Readout does not work on the VE.Can port with a VE.Bus to VE.Can interface cable.
  • On MultiPlus-II hardware revision 0 to 8, the AUX input is on the RJ12 connector, pins 1 and 5. Later revisions have the AUX input as a normal terminal.
  • Inverter/charger firmware must be 2xx or later. The GX device needs at least v1.30, and a more recent version is required.
  • The Victron CSE000100000 should not be confused with the Current Transformer 100A:50mA accessory for MultiPlus-II, part number CTR110000500.