Description
The Victron BlueSolar MPPT 150/35 is a solar charge controller that moves power from your solar panels into your batteries. It uses MPPT (Maximum Power Point Tracking) to keep checking panel voltage and current, which Victron says pays off most when the sky is partly clouded. It auto-selects 12 V, 24 V or 48 V battery systems.
Features
- Rated charge current of 35 A from one tracker.
- Maximum PV open circuit voltage of 150 V and maximum PV short circuit current of 40 A per tracker.
- Battery voltage of 12 V, 24 V or 48 V, set by auto select.
- Starts when PV voltage exceeds battery voltage by 5 V; afterwards the minimum PV voltage is battery voltage plus 1 V.
- Maximum efficiency of 98 %, with multi-stage adaptive charging that can be adjusted.
- Protects against PV reverse polarity, output short-circuit and excessive temperature.
- Uses VE.Direct data communication; Victron’s page describes monitoring with a Bluetooth dongle and VictronConnect, or with a GX device and the VRM portal.
Specifications
| Part number | SCC020035000 |
| UPC/EAN | 8719076025559 |
| Rated charge current | 35 A |
| Battery voltage | 12 V / 24 V / 48 V (Auto Select) |
| Number of trackers | 1 |
| Maximum PV open circuit voltage | 150 V |
| Maximum PV short circuit current per tracker | 40 A |
| Nominal PV power | 500 W at 12 V, 1,000 W at 24 V, 1,500 W at 36 V, 2,000 W at 48 V |
| Charge voltage float | 13.8 V / 27.6 V / 55.2 V (adjustable) |
| Charge voltage absorption | 14.4 V / 28.8 V / 57.6 V (adjustable) |
| Temperature compensation | -16 mV/°C at 12 V, -32 mV/°C at 24 V, -64 mV/°C at 48 V |
| Start-up PV voltage | PV voltage must exceed Vbat + 5 V to start; afterwards minimum PV voltage is Vbat + 1 V |
| Self-consumption | 12 V: 20 mA, 24 V: 15 mA, 48 V: 10 mA |
| Maximum efficiency | 98 % |
| Protections | PV reverse polarity, output short-circuit, excessive temperature |
| Data communication | VE.Direct |
| PV connection terminal type | Screw terminals 16 mm² (6 AWG) |
| Battery connection terminal type | Screw terminals 16 mm² (6 AWG) |
| Protection category | IP22 (connection area), IP43 (electronic components) |
| Operating temperature range | -30 °C to 60 °C |
| Safety standards | CSA C22.2, EN-IEC 62109-1, UL 1741 |
| Colour | Blue (RAL 5012) |
| Width | 186 mm |
| Height | 130 mm |
| Depth | 70 mm |
| Weight | 1.25 kg |
Warranty and support
Victron lists a 5-year standard warranty and global repair service. The page directs warranty and repair requests to your original dealer, with support resources available online.