Raritan CH120 Pump Wall for Crown Head Discharge Series

$23.10 USD

Raritan CH120 pump wall, a replacement part for Crown Head Centrifugal Discharge Series units with a standard size bowl and 90° discharge fitting. It is folded to fit inside the end bell and sits behind the internal channels.

Ships from manufacturer within 2 weeks

Description

The Raritan CH120 pump wall is a replacement pump wall for the Crown Head Centrifugal Discharge Series. Raritan’s repair guide covers units with a standard size bowl and 90° discharge fitting. The new wall is larger than the end bell opening, so it is folded to fit inside before it is seated.

Features

  • Replacement pump wall, part number CH120
  • Listed for the Crown Head Centrifugal Discharge Series with a standard size bowl and 90° discharge fitting
  • Larger in diameter than the end bell opening, so it is folded to fit inside
  • Sits behind the internal channels and against the CH119MW
  • The CH121 blade threads onto the CH119MW hand tight only

Specifications

Part number CH120
UPC 85462005954
Brand Raritan
Series Crown Head Centrifugal Discharge
Bowl size Standard size
Discharge fitting 90°

Replacement steps

  1. Remove the CH29 shroud assembly from the lower unit to expose the CH18W front cover, then take the CH18W cover off with a flat blade screwdriver.
  2. Unscrew the CH121 macerator blade counterclockwise and remove the old pump wall or any remaining pieces.
  3. Fold the new CH120 to fit through the end bell (CH15DD), push it all the way in behind the internal channels, then press it against the CH119MW.
  4. Thread the CH121 back onto the CH119MW hand tight only, then refit the CH18W cover.

Raritan lists standard or needle nose pliers and a medium flat blade screwdriver as the tools for this job.

Series and fitting

Listed for the Crown Head Centrifugal Discharge Series with a standard size bowl and 90° discharge fitting.