Description
The Raritan CH120 pump wall is a replacement pump wall for the Crown Head Centrifugal Discharge Series. Raritan’s repair guide covers units with a standard size bowl and 90° discharge fitting. The new wall is larger than the end bell opening, so it is folded to fit inside before it is seated.
Features
- Replacement pump wall, part number CH120
- Listed for the Crown Head Centrifugal Discharge Series with a standard size bowl and 90° discharge fitting
- Larger in diameter than the end bell opening, so it is folded to fit inside
- Sits behind the internal channels and against the CH119MW
- The CH121 blade threads onto the CH119MW hand tight only
Specifications
| Part number | CH120 |
| UPC | 85462005954 |
| Brand | Raritan |
| Series | Crown Head Centrifugal Discharge |
| Bowl size | Standard size |
| Discharge fitting | 90° |
Replacement steps
- Remove the CH29 shroud assembly from the lower unit to expose the CH18W front cover, then take the CH18W cover off with a flat blade screwdriver.
- Unscrew the CH121 macerator blade counterclockwise and remove the old pump wall or any remaining pieces.
- Fold the new CH120 to fit through the end bell (CH15DD), push it all the way in behind the internal channels, then press it against the CH119MW.
- Thread the CH121 back onto the CH119MW hand tight only, then refit the CH18W cover.
Raritan lists standard or needle nose pliers and a medium flat blade screwdriver as the tools for this job.
Series and fitting
Listed for the Crown Head Centrifugal Discharge Series with a standard size bowl and 90° discharge fitting.